Specifications for GX41 |
 |
UIS optics for excellent optical performance
Portable and easy to carry
Mirror stage for convenient specimen confirmation
Highly expandable system |
Back to main page |
Print |
Frame
| Name |
Description |
Article Code |
| GX41F |
Inverted metallurgical microscope frame with left-side tilted quadruple nosepiece and maximum field number 22. For reflected light brightfield and reflected light simple polarising observation. Coarse and fine focussing knobs with maximum focus stroke of 9mm and 200 µm stroke per full rotation of the fine focus knob. With fixed stage and integrated transformer (6 V/30W) and front control of the light intensity. With slots for filters, polariser and analyser. |
N1497200 |
| UYCP |
Power cord |
35425 |
Stage Accessories
| Name |
Description |
Article Code |
| CK40-MVR |
Attachable specimen guide, right-hand low driven coaxial stage control, movement range: x=120mm, y=78mm, with 3 inserts: 1) for slides and Petri dishes 54mm ø, 2) for microtiter plates (60 or 72) & Petri dishes 65mm ø, 3) plate 80x55mm for Petri dishes 30mm ø |
31538 |
| CK40M-CP |
Stage plate for stage plate holder to be used with CK40-MVR |
32319 |
| GX-CP |
Stage insert plate set incl. droplet stage insert plate and oblong hole stage insert plate, diameter: 110mm |
036088 |
| IX-CP50 |
Stage insert plate for IX and CK40 stages, inner diameter 50 mm |
37397 |
| CK40M-MS |
Stage mirror |
35486 |
Observation Tubes and Intermediate Tubes
| Name |
Description |
Article Code |
|
Observation Tubes |
|
| CKX-TBI |
Tilting binocular tube for CKX41 with FN20, variable inclined angle is 30°-60°, interpupillary distance between 50-76 mm, diopter adjustment by helicoid on right side sleeve, 2 eye-pieces for FN 20 are included. |
N1182600 |
| U-CTBI |
Tilting observation tube, FN18 for CX and CKX |
N1488300 |
| U-CBI30-2-2 |
Binocular tube with leadfree optics, 30° inclination and pupillary distance adjustment from 48-75 mm. Adjustable diopter range (± 5 diopter) on left sleeve. To be used WHB10x, WHB10x-H eye-pieces and field-number 20. |
N1468300 |
| U-BI30-2-2 |
Binocular (Siedentopf) tube with leadfree optics, 30° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on left sleeve. To be used with WHN10x/22, WHN10x-H/22 eyepieces. |
N1468700 |
|
|
|
| U-TBI-3 |
Tilting binocular tube, inclination 5-35°, interpupillary distance adjustment 48-75mm, with diopter adjustment on left sleeve |
037121 |
|
|
|
| U-TR30-2-2 |
Trinocular tube with 30° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on left sleeve. To be used with WHN10x/22 , WHN10x-H/22 eyepieces. Beamsplitter for 3 positions (100/0, 20/80, 0/100). |
N1512000 |
| U-CTR30 |
Phototube 30° inclined, for WHB10x(H) eyepieces, field number 20, fixed light distribution 50/50, interpupillary distance adjustment 48-75 mm with diopter adjstment on left sleeve, FN20. |
38713 |
|
|
|
|
Intermediate Tubes |
|
| GX41-EPA |
Eyepoint adjuster for GX41 |
N1501200 |
| GX-SPU-1-2 |
Intermediate attachment tube with side port, dovetail mount to use with GX51 (not for GX71) to combine with the BX-TV adapter U-TV0.5xC, U-TV0.35xC and U-TV1x, not to use with other TV adapter combinations |
N2193100 |
| U-CA |
Magnification changer 1x/1.25x/1.6x/2x |
037205 |
| U-ECA |
Magnification changer 1x/2x |
037222 |
| U-ECA1.6X |
1.6X magnification Changer with two positions 1X/1.6X |
38741 |
Eyepieces
| Name |
Description |
Article Code |
| WHN10X/22 |
Widefield eyepiece, FN22 |
N1508000 |
| WHN10X-H/22 |
Widefield eyepiece, focusable, FN22 |
N1508100 |
| CROSSWHN10X/22 |
Focusable widefield eyepiece with cross lines, fieldnumber 22. |
N1508400 |
Eyepiece Micrometers and Graticules
| Name |
Description |
Article Code |
| |
Micrometers |
|
| 20.4-RH |
Holder for reticles with 20.4 mm ø, for eyepiece WHB10x and WHB10x-H |
N1209500 |
| 20,4-10/100 EYEP.MICRO. |
Eyepiece micrometer, 10mm/100 ticks, 20.4mm ø |
35040 |
| 20,4-CROSS HAIR ONLY EYEP |
Eyepiece micrometer cross-hair, 20.4mm ø |
35041 |
| 20,4-10/100 EYEP.MICRO. |
OCM Eyepiece micrometer cross with x-axis, 10mm/100 ticks, 20.4mm ø |
35042 |
| 20,4-10/100,XY EYEP.MICRO |
OCM Eyepiece micrometer cross with x/y-axis, 10mm/100 ticks, 20.4mm ø |
35043 |
| 20,4-SQUARE 5/5X5 EYEP.MI |
OCM Eyepiece grid micrometer, 5x5mm/5 ticks, 20.4mm ø |
35044 |
| 20,4-SQUARE 7/7X7 EYEP.MI |
OCM Eyepiece grid micrometer, 7x7mm/7 ticks, 20.4mm ø |
35045 |
| 20,4-SQUARE 5/10X10 EYEP. |
OCM Eyepiece grid micrometer, 5x5mm/10 ticks, 20.4mm ø |
35046 |
| 20,4-SQUARE 10/10X10 EYEP |
OCM Eyepiece grid micrometer, 10x10mm/10 ticks, 20.4mm ø |
35047 |
| |
Graticules |
|
| U-OCMGS |
Grain size scale |
35069 |
| U-OCM10/100 |
10mm/100 |
35070 |
| U-OCMCROSS |
Cross lines only |
35071 |
| U-OCMC10/100X |
Cross lines and 10mm/100 on X |
35072 |
| U-OCMC10/100XY |
Cross lines and 10mm/100 on X and Y |
35073 |
| U-OCMSQ5/5 |
Square 5mm/5 |
35074 |
| U-OCMSQ5/10 |
Square 5mm/10 |
35076 |
| U-OCMSQ10/10 |
Square 10mm/10 |
35077 |
| U-OCMSQ10/100 |
Square 10mm/100 |
35078 |
|
Objectives
| Name |
Description |
Article Code |
| MPLN5X |
Material science plan achromat objective. Magnification 5x, numerical aperture 0.10, working distance of 20.0mm, maximum field of view 4.40mm. The objective is suitable for reflected and transmitted light observations. |
N2180500 |
| MPLN10X |
Material science plan achromat objective. Magnification 10x, numerical aperture 0.25, working distance of 20.0mm, maximum field of view 2.20mm. The objective is suitable for reflected and transmitted light observations. |
N2180600 |
| MPLN20X |
Material science plan achromat objective. Magnification 20x, numerical aperture 0.40, working distance of 1.3mm, maximum field of view 1.10mm. The objective is suitable for reflected and transmitted light observations. |
N2180700 |
| MPLN50X |
Material science plan achromat objective. Magnification 50x, numerical aperture 0.75, working distance of 0.38mm, maximum field of view 0.44mm. Spring loaded front lens. The objective is suitable for reflected and transmitted light observations. |
N2180800 |
|
|
|
| MPLN100X |
Material science plan achromat objective. Magnification 100x, numerical aperture 0.90, working distance of 0.21mm, maximum field of view 0.22mm. Spring Loaded front lens. The objective is suitable for reflected and transmitted light observations |
N2180900 |
Polarisation Equipment
| Name |
Description |
Article Code |
| CK40M-AN |
Analyser for CK40M and GX41 |
32317 |
| CK40M-PO |
Polariser, holder 29mm ø |
32318 |
|
Discussion Unit and Drawing Attachment
| Name |
Description |
Article Code |
|
Discussion Unit |
|
| U-DO3-2 |
Dual viewing observation attachment incl. LED arrow pointer with AC power supply |
N2215800 |
| UYCP |
Power Cord |
35425 |
|
Intermediate Macro Attachment U-DA |
|
| U-DA |
Macro/Drawing attachment |
037219 |
| KL 1500 LCD |
KL1500LCD cold light source with 15V/150W halogen lamp, electronical (6 stages) and mechanical (5 stages) light intensity adjustment, LCD-Display, max. active diameter of the light guide: 9mm, integrated swing out focussing lens, build-in transformer 230V |
E0433003 |
| KL-JRL |
Ring light "Jumbo", adaptation diameter 66mm, active diameter 13mm, length of the flexible light guide 1000mm, exclusively to be used with KL2500LCD |
E0433022 |
| U-DA-AD |
Magnification changer 1x/1.25x/1.6x/2x |
E0432089 |
| UYCP |
Power Cord |
35425 |
Lamphouse and Lighting Equipment
| Name |
Description |
Article Code |
|
Lamphouse |
|
| U-LS30-3-2-5 |
30W Halogen lamphouse, to mount on IX50, IX51, CK40M, GX41, CKX31 and CKX41 |
N2211900 |
|
Lighting Equipment |
|
| KL 2500 LCD |
KL2500LCD cold light source with 24V/250W halogen lamp, electronical (6 stages) and mechanical (5 stages) light intensity adjustment, LCD-Display (displays the colour temperature and electr. malfunction message), max. active diameter of the light guide: 15mm, integrated swing out focussing lens, front located connector for electr. accessories (remote control, tilt switch, RS232 interface), integrated 5 positioned filter wheel (Filterdiam. 32mm), build-in transformer 230V/50Hz, incl. Power cord |
E0433003 |
| KL-JRL |
Ring light "Jumbo", adaptation diameter 66mm, active diameter 13mm, length of the flexible light guide 1000mm, exclusively to be used with KL2500LCD |
E0433022 |
| KL-BL-18TL-2 |
One-armed flexible light guide, effective diameter 8mm, length 1000mm, to combine with SZX-TLGAD |
E0433196 |
| SZX-TLGAD |
Adapter to fix the KL-BL18/1000TL on SZX-ILLB/D/K transmittance stands |
33747 |
Camera Adapter
| Name |
Description |
Article Code |
|
| U-TV1x-2 |
Direct image video adapter tube 1x |
037175 |
| U-CMAD3 |
C-mount adapter ring |
037194 |
| U-TV0.5xC-3 |
Camera adapter with C-mount, 0.5x magnification gives full fieldnumber (FN) 22 on 2/3“ CCD camera chips. With high IR transmission. |
N1512100 |
| U-TV0.35xC2 |
Camera adapter with C-mount, 0.35x magnification factor gives full fieldnumber (FN) 22 on 1/2“ CCD camera chips. With high IR transmission. |
N1512200 |
| C5060-ADU |
C-Mount Microscope Adapter for UIS Optics and competitors microscopes |
N1492500 |
| C5060-ADUS |
Eyepiece Sleeve mount Microscope Adapter for use on Observation Tubes |
N1492400 |
|
|
|