Resolution: 2576 x 1932 pixels
Binning: 2x, 4x, 6x
Dynamic range: 3 x 12bits
Exposure time: 1ms – 160 sec
Frame rate: > 19 fps @ 6x binning
Cooling: Peltier cooled |
Back to main page |
Print |
 |
 |
Becke line |
| |
The Becke line appears as a band of light along the boundary between two media with different... More
|
 |
 |
Binning |
| |
Binning, also called on-chip integration, is the combination of the charges of neighboring CCD pixels during readout.... More
|
 |
 |
Bit Depth of Camera Data |
| |
The bit depth refers to the digitization of the analogue light signal by the analogue-to-digital (A/D) converter... More
|
 |
 |
Blooming |
| |
If a CCD is overexposed, that is, if the illumination exceeds the full-well capacity of the photodiodes... More
|
 |
 |
Cathodic vacuum etching |
| |
The prepared and scratch-free specimen forms the cathode in a vacuum glow discharge chamber. During the etching... More
|
 |
 |
CCD |
| |
The acronym CCD stands for "charge-coupled device". CCDs are used as electronic light sensors: Photons hitting the... More
|
 |
 |
CCD Chip Size |
| |
The CCD chip size is often given in an inch measure: 1/2" chip, 2/3" chip, etc. Counter... More
|
 |
 |
CCD Chip Types |
| |
Back-thinned, back-illuminated CCD chips
This is a rather expensive and delicate type of chips for high-end scientific-grade... More
|
 |
 |
Chemical Etching |
| |
After sectioning and grinding several cycles of etching and polishing remove
disturbed metal layers from the surface of... More
|
 |
 |
Concrete |
| |
Optical microscopy is an important tool to analyse concrete and related materials (building stones, bricks …). Semitransparent... More
|
 |
 |
Data Readout Rate |
| |
Usually the rate limiting step is analogue-to-digital signal conversion. The conversion rate ranges somewhere between 1 and... More
|
 |
 |
Digital images |
| |
Digital image files are based on tables that list the intensities, or "counts", of all pixels. In... More
|
 |
 |
Dynamic Range |
| |
The dynamic range of a CCD camera (DR) is the maximum signal (which is directly related to... More
|
 |
 |
Electrolytic Etching |
| |
Some materials react very slow to chemical etching (eg. stainless steel,
chromium, nickel and cobalt based materials).... More
|
 |
 |
Embryonic stem cells |
| |
Embyronic stem cell lines, which were originally produced from the inner core of human blastocysts as well... More
|
 |
 |
Etching |
| |
To enhance the contrast of a metal surface for observation in reflected light
microscope etching is a... More
|
 |
 |
FireWire |
| |
The IEEE1394, also called FireWire, is a modern plug-and-play interface between PC and camera (or other peripherals,... More
|
 |
 |
Full-Well Capacity |
| |
This is the maximum amount of charges (electrons) the photodiodes of a CCD chip can accommodate. It... More
|
 |
 |
Gout microscopy |
| |
One of the most common medical applications for polarised light microscopy is the identification of gout crystals... More
|
 |
 |
Michel Levy |
| |
The birefringence of an anisotropic material can be estimated when observed
and/or photographed in a polarised light... More
|
 |
 |
Oblique Illumination |
| |
Achieving conditions necessary for oblique illumination, which has been
employed to enhance specimen visibility since the dawn... More
|
 |
 |
Optical Etching |
| |
Depending on the alloy the surface of an as-polished specimen can be optically
etched by using light... More
|
 |
 |
Phase Contrast |
| |
Phase contrast was introduced in the 1930's for testing of telescope mirrors, and was adapted by Zeiss... More
|
 |
 |
Pixels |
| |
Digital images are made up of many thousands or even millions of tiny squares (or rectangles) called... More
|
 |
 |
Reflected Darkfield Microscopy |
| |
Darkfield illumination with reflected light enables visualisation of grain boundaries, surface defects, and other features that are... More
|
 |
 |
Rock formation |
| |
As well as providing information on component minerals, an examination of
geological thin sections using polarising microscopy can... More
|
 |
 |
Semiconductor Wafer Inspection |
| |
By using reflected light microscopy wafers can be inspected for contaminants,
roughness or flatness. Brightfield, darfield, and DIC... More
|
 |
 |
Shading |
| |
Gradual noise and sensitivity variations across the CCD chip and the corresponding inherent intensity gradients in the... More
|
 |
 |
Slow-Scan Cameras |
| |
CCD cameras are often termed slow-scan cameras because their standard frame rate is usually less than that... More
|
 |
 |
Twinning |
| |
A twinned crystal consists of two or more parts with different crystallographic orientations. The crystals lattice of... More
|
 |
 |
Well depth |
| |
The well depth is the maximum amount of charges (electrons) the photodiodes of a CCD chip can... More
|
|
|
|
.gif) |
 |
ColorView III related Application Report |
|
|
|
|
|